How to maintain the capsule filling machine:
1. When the machine works normally for a long time, it is necessary to regularly clean the parts that are in direct contact with the drug. When the drug batch is replaced or the machine is out of use for a long time, it must also be cleaned.
2. The transmission mechanism under the working surface of the machine should be regularly and appropriately added lubricating oil (grease) to reduce the wear and tear of moving parts.
3. The oil quantity of the main transmission reducer should be checked once a month. If it is insufficient, it should be refueled in time, and the lubricating oil should be replaced every six months; #motor oil.
4. The safety clutch plays a protective role when the machine is overloaded. When the load is normal, the clutch should not slip, but it may slip due to long-term use. When slipping occurs during normal use, the round nut of the clutch can be tightened. Some, achieve the purpose of ensuring the normal operation of the machine and protecting it.
5. The transmission chain should be checked once a week, and an appropriate amount of grease should be added, and re-tightened if necessary. When the chain is too loose and needs to be re-tightened, the tensioning wheel should be moved for adjustment, but the chain cannot be opened or separated from the sprocket, so as not to disrupt the movement sequence of the entire mechanism and prevent the mechanism movement interference.
6. The vacuum separator of the vacuum system mainly plays the role of sucking the capsules into the upper and lower modules and separating the cap and body during the filling of empty hard capsules. If the capsule cannot be separated from the cap and body, the subsequent filling will not be possible. Every time the turntable of the machine rotates one station, the main shaft of the machine rotates one revolution, and the vacuum separator moves up and down once under the action of the cam. If the capsule cap and body are not separated smoothly, check the gap between the upper plane of the vacuum separator and the lower plane of the lower module. If the gap is too large, the vacuum degree of the vacuum system will not reach the required vacuum degree for cap and body separation ( 0.05MPa or so), the gap is too small and it is easy to produce bumps to deform the lower module. When the position of the vacuum separator needs to be adjusted, turn the main motor shaft with the handle to raise the vacuum separator to the highest position, and loosen the lock nuts at both ends of the adjustment rod under the machine table (one is a left-handed nut and the other is a right-handed nut) ), then rotate the adjusting rod to adjust the height of the vacuum separator, then lock the nut, and use the handle to turn the main motor shaft until it is suitable. The vacuum degree is read on the vacuum gauge on the machine operation panel. When the vacuum is too high, the vacuum degree regulating valve can be opened properly, and when the vacuum degree is too low, the vacuum degree regulating valve can be turned down or closed. The filter of the vacuum system should be opened regularly to clean up the clogged dirt to ensure that the vacuum system has a sufficient vacuum.